| Model | Operating Pressure psi (MPa) | Permeate Flow GPD (m³/d) | Stable Salt Rejection (%) | Minimum Salt Rejection (%) |
| RO 2812-200 | 44-145/0.3-1 | 200 | 98 | 97 |
Maximum Operating Limits
- Max operating pressure: 150 psi (1.03 MPa)
- Max feed water temperature: 45°C
- Max feed water SDI15: 5
- Max free chlorine concentration: 0.1 mg/L
- Continuous operation feedwater pH range: 4–11
- Cleaning pH range: 2–11
- Max pressure drop per element: 15 psi (0.1 MPa)
Notes:
1. Max temperature for continuous operation at pH > 10: 35°C
2. Under certain conditions, the presence of free chlorine or other oxidants may cause irreversible damage to membranes. Pre-treatment to remove free chlorine is recommended.
Stay In The Know
Centro de sustituciones y repuestos
Encuentre una alternativa compatible de BOKAWATER
Busque una marca, un modelo, un SKU o un tipo de producto instalado. El selector de membranas RO ya está disponible; las demás categorías se revisan mediante ingeniería con placa o BOM.Centro de soluciones BOKAWATER
Encuentre productos, soluciones de ingeniería y sustituciones compatibles
Comience por el equipo, el problema del agua o el componente instalado. Cada ruta conduce a datos técnicos y una consulta específica.ProductosSistemas RO, membranas, tratamiento de aguas residuales y equipos de proceso.SolucionesSeleccione por agua de alimentación, industria, objetivo y capacidad.Sustituciones y repuestosBusque productos estándar y solicite una alternativa con confirmación técnica.ProyectosRevise aplicaciones y referencias de sistemas suministrados.Centro de conocimientoRespuestas técnicas, comparaciones, mantenimiento y selección.CatálogosDatos de producto, especificaciones y material técnico descargable.